GYPSUM FIBRE FLOORING SYSTEMS

ARRANGEMENT OF SYSTEMS

System flooring solutions with gypsum fiber products are arranged according to their application area. A leading factor in the classification is load bearing capacity systems, subsequently structuring the variants of the respective construction-physical characteristics, type of substructure and the accompanying materials and accessories. Hopefully, we will give a good and complete synergy between different systems to make it easier for you to choose.

          Loading areas acc. EN 1991-1-1:

  • Application category A
  • Application category B
  • Application category C1 
  • Application category C2



APPLICATION CATEGORY A 

acc. EN 1991-1-1:


Category A - Rooms in residential buildings and houses; Bedrooms and wards in hospitals; Bedrooms in hotels and hostels kitchens and toilets.

Substructure: reiforced concrete floor

Description

Rigidur flooring element 20 (2x10 mm)                                      

Rigidur flooring element 25 (2x12,5 mm)                                                 

Knauf Brio 18 mm + 20 mm EPS*                       

Knauf Vidifloor Solo 18 mm + 20 mm EPS*   

Knauf Vidifloor Solo 18 mm + 20 mm MW                                                   

Knauf Brio 18 mm + 10 mm WFB*                                                      

Fermacell 2 E 22 (2x12,5 mm) + 30 mm UFH*                                            

Knauf Vidifloor Solo + 9.5 mm GKB* + 30 mm LC                                        

Knauf Brio 18 mm + 10 mm WFB + 20 mm LC                                             Fermacell 2 E 22 (2x12,5 mm) + 17/16 mm WFB*                                        Fermacell 2 E 32 (2x10 mm + 10 mm MW*)                                                Knauf Vidifloor Solo + 9.5 mm GKB* + 40 mm LC                                         Fermacell 2 E 22 (2x12,5 mm) + 100 mm LC*                                              Knauf Vidifloor Solo + 9.5 mm GKB* + 50 mm LC                                         Knauf Brio (2x23 mm) + 20 mm MW                                                

Fermacell 2 E 22 (2x12,5 mm) + 20/21 mm WFB + 20 LC                             Fermacell 2 E 22 (2x12,5 mm) + 100 mm MW                                              Fermacell 2 E 35 (2x12.5 mm + 20 mm MW)                                               Fermacell 2 E 31 (2x10 mm + 10 mm MW) + 100 mm LC                             Knauf Brio 23 mm + 12 mm MW + 10 mm WFB + 20 mm LC                        Fermacell 2 E 22 (2x12,5 mm) + 160 mm MW                                             Fermacell 2 E 32 (2x10 mm + 10 mm MW*) + 20 mm LC                              Fermacell 2 E 22 (2x12,5 mm) + 30 mm UFH* + 10 mm GFB + 20 mm MW    Fermacell 2 E 35 (2x12.5 mm + 20 mm MW) + 20 mm LC                             Fermacell 2 E 32 (2x10 mm + 10 mm MW*) + 60 mm LC                           


Fire Protection

30 min

30 min    

30 min    

 -            

 -            

 -            

60 min    

 -            

60 min    

60 min    

60 min   

 -           

120 min  

 -            

30 min    

60 min

60 min   

90 min    

120 min    

90 min      

60 min     

60 min      

60 min      

90 min     

120 min          

Impact sound

16 dB    

 -        

16 dB

17 dB

17 dB

19 dB

20 dB

20 dB

22 dB

22 dB

22 dB

22 dB

24 dB

24 dB

26 dB

27 dB

27 dB

27 dB

27 dB

28 dB

29 dB

29 dB

30 dB

31 dB

31 dB


 

Substructure: Closed wooden joist floor

Description

Fermacell 2 E 32 (2x10 mm + 10 mm MW*)

Fermacell 2 E 35 (2x12.5 mm + 20 mm MW)

UFH = unterfloorheating

WFB = wood fibre board

MW = mineral wool

LC = leveling compound

GFB = gypsum fibre board

GKB = gypsum plaster board  EPS = expanded polystyrene

Fire Protection


Impact sound

51 dB

48 dB


Airborne sound

65 dB